Capsule Pressure Gauges (PCX Series)

PCS063, PCS100
PCX100, PCX150

For measurement of low pressure and vacuum within the range -600…0 to 0…600 mbar, for use on gas and dry air.

Functional and constructive characteristics

PCS063… (without filling)
Accuracy class : 1.6 as per EN 837.
Ambient temperature : -25…+65°C.
Process temperature : +50°C.
Overpressure : 25% of full scale value.
Socket material : nickel plated brass.
Elastic element : phosphor bronze capsule
Case : stainless steel.
Ring : stainless steel.
Window : glass.
Movement : brass.
Dial : aluminium, white with black marking.
Special dial : ranges different from standard,
available on request.
Pointer : aluminium alloy.
Blow out vent : EPDM.

Functional and constructive characteristics

PCS100… (without filling)
Accuracy class : 1.6 as per EN 837.
Ambient temperature : -25…+65°C.
Process temperature : +65°C.
Overpressure : 25% of full scale value.
Socket material : AISI 303 st.st.
Elastic element : phosphor bronze capsule.
Case : stainless steel.
Ring : stainless steel.
Window : glass.
Movement : brass.
Dial : aluminium, white with black marking.
Special dial : ranges different from standard,
available on request.
Pointer : aluminium alloy.
Blow out vent : EPDM

Functional and constructive characteristics

PCX100-150… (without filling)
Process temperature : +100°C.
Socket material : AISI 316 st.st.
Elastic element : AISI 316 Ti st.st.(1.4571) capsule
Other characteristics : as type PCS100.
Options : on request